SECTION 3 DEX HEATED REGENERATIVE DRYER
 15
3.6 ELECTRICAL DATA
3.7 TIME, PRESSURE, 
TEMPERATURE, AND 
DEWPOINT SETTINGS
3.8 DIMENSIONS AND WEIGHT
3.9 FILTER MODELS
Power Supply 480 volt, 3 phase, 60 Hz
Installed power _____KW
Electrical Encolsure NEMA 12
Control voltage 120 Volts A.C.
Solenoid coil voltage 120 Volts A.C.
Adsorption time  240 minutes
Regeneration time 240 minutes
Heating time 140 minutes
Cooling time 100 minutes
Heater outlet 
temperature
350°F
Regen. heater 
sheath over temp. 
650°F
Adsorption pressure 100 Psig (minimum)
Dewpoint controlled 
changeover
-40°F
High Dewpoint 
alarm setting
+32°F
Width _____”inches
Height _____”inches
Depth _____”inches
Weight Approx. _____lbs
Pre-filter Model _____
Pre-filter element _____
After filter model _____
After filter element _____
Control Air Filter  _____
Control Air Element _____