EasyManua.ls Logo

Sumitomo F-20L - MAINTENANCE; Adsorber Replacement Procedure

Sumitomo F-20L
56 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MAINTENANCE
33
Adsorber Replacement
Part required: Adsorber, P/N F300138A
Tools required: #2 Phillips screwdriver
Open-end wrenches, 1", 1 1/8", 1 3/16"
Snoop
®
AVOID EQUIPMENT FAILURE OR CONTAMINATION. Use SHIG adsorber
P/N F300138A only. Use of non-SHIG spare parts will void the warranty.
The compressor’s adsorber should be replaced every 30,000 operating hours (40 months).
The used adsorber has no salvage or repair value. Venting the compressor is not required
when replacing the adsorber because the gas couplings are self-sealing
Adsorber Removal
1. Stop the compressor and disconnect the power to the compressor.
2. Using two wrenches, disconnect the high pressure (supply) gas line from the helium high
pressure coupling on the compressor. Screw a dust plug into the disconnected gas line.
NOTE
Always hold the stationary nut on the gas line coupling with one wrench while
turning the moveable coupling with the other wrench.
3. Remove the compressor’s cover panel. See Figure 8.
Figure 8 Compressor Cover Panel Removed

Related product manuals