19
Explosion-proof motor series
Explosion-proof motor series with
protection type "frameproof (d2G4)".
HF-320
200 V class 0.2 kW model alone is available.
(Products are made according to customer's specifications.)
The output base frequency is 60 Hz only. Any other base frequency setting may cause fire. Be sure to set the base frequency at
60 Hz.
The explosion-proof (d2G4) motor is used only with HF-320 Series, and it cannot be used with SF-320 Series. Set the inverter to
"Sensorless vector control."
kWP
0.24
T-71S
T-80M
T-90L
T-100L
T-112M
T-132MS
0.44
0.754
1.54
2.24
3.74
Motor
frame
No.
Specifications
Scope of
manufacture
Insulation Characteristics
Output base
frequency
Protection type
Indoor
JP44
Outdoor
JPW44
Starting
torque
Constant
power
range
1. Available
Direct coupling
with CYCLO
Outdoor
JEM flange
Foot mounted
2. Unavailable
With PG
With brake
Class
B
1:20
Constant
torque
Continuous
rating
Dedicated
to
60 Hz
200%
or
more
120Hz
110Hz
100Hz
Totally-enclosed
self-cooled
Totally-enclosed
fan-cooled
Specifications
Option
1. Control range: 1:20 wide-range control
2. Starting torque: 200% or more
3.
Speed fluctuation:±1% accuracy
(Sensorless vector control operation)
Operator station specifications for Exd2
Model No.
Ordering type
Frequency counter
Volume
Pilot lamp
Operation switch
EGFCT3203
OS1-Exd2- - OS2-Exd2- - OS3-Exd2- - OS4-Exd2- -
Scale: 0-100% (Special scale is also available.)
RA30YN-2W 1k
ON-OFF
selector switch
Reverse-Stop-Normal
selector switch
Normal-Reverse
selector switch
ON-OFF
pushbutton switch
Power indication Power indication Power indication
Features
Ordering type OS1-Exd2- 2 -
1. Pilot lamp power: 24 VDC
2. Pilot lamp power: 100 VAC
3. Pilot lamp power: 200 VAC
Meter input specifications: 0-10 V.F.S.
Contact us when the wiring distance exceeds 30 m.
NEW
NEWNEW
200V400V class