20
Terminal Functions
Main Circuit Terminals
Symbol Terminal name Explanation
Ground to prevent electric shock
and reduce noise.
Connect the motor
Connect the input power supply
Ground
PPR: Regenerative braking resistor
(Note 1)
P-P1: Short bar or
DCL
Inverter output terminals
Main power supply input terminals
PR,P,
P1,N
U,V,W
R,S,T
[Main circuit terminals] [Control circuit terminals]
Main circuit terminals Front case (right open)
Ternimal section cover (left open)
Control circuit terminals
Regenerative
braking resistor
(option)
MCB
Motor
RSTP1PNPRUVW
AC reactor
(option)
DC reactor
(option)
Power supply
(Note 1) Contact our company when continuous regenerative operation is desired.
Terminal Functions
Regenerative breraking registor
terminals
Connect the DC reactor for harmonic
suppression. Power factor improvent
Monitor terminal (frequency, current, etc.)
Common terminal for monitor and frequency command
External DC power supply
Intelligent input terminals:
Select from forward run command, reverse run command,
multispeed commands, 2-stage acceleration/deceleration command,
free run stop, external trip, jogging, analog input selection, software
lock, reset, and initial setting. Un attended start prevention.
Intelligent onput terminals:
Select from run, overload, alarm,frequency match, and set frequency
defect.
Alarm output terminals (IC contact (relay) output)
Common terminal for
frequency command
Frequency command
input (current command)
Frequency command
input (voltage command)
Power supply for
frequency command
PWM output DC 10V 1mA
DC24V, Max.30mA
DC10V
DC010V(Variable by parameter)
Input impedance 10k
DC420mA (Variable by parameter)
Input impedance 250
Open collector output
L level at operation (ON)
DC27V, Max.50mA
Control Circuit Terminal
Symbol Terminal Name Remarks
FRQ
COM
PCS
RST
DFM, DFH
DFL
RR
FR
+V
VRF
IRF
COM
DRV
UPF
OM
AL2
AL1
AL0
Input / Monitor signalFrequency command
(Note 1)
Output signal
Alarm output
Alarm terminal
Ground
Control circuit
terminals
Main circuit
terminals
M4(M3.5) 9(7.1)
M2 (press-tight type)
M3 (press-tight type)
M4
Terminal
width
Terminal screw
diameter
(Note 1) The maximum frequency command is 9.8 V when the voltage input is 0-10 VDC, and 19.6 mA when the current input is 4-20 mA.
(Note 2) The reset terminal cannot be changed to [Operation with (SW) Open].
AL0 AL1 AL2
Initial setting
When normal, power OFF: AL0-AL2 Close
When alarm: AL0-AL2 Open
(Switchable to AL0-AL1 Close when normal.)
Operation by SW Close.
(Changeable to operation by SW Open.)
(Note 2)
Minimum ON time: 12 ms or more
( ) : HF3202-A20A75
(1k2k)
VRO
DC010V
Input impedance 10k
+
DC420mA
Input impedance 250k
+
When the analog input selection is not assigned to the multifunctional input
terminal, the frequency obtained by adding the voltage command value and
current command value is output. When either voltage or current is selected,
be sure to allot the analog input selection to the multifunctional input terminal.
+V
VRF IRF
COM
+V
VRF IRF
COM
+V
VRF IRF
COM
Note:
SW
FR,RR,RST
DFH,DFM,DFL
COM
HF-320
Contact input

Related product manuals