26
Applicable Wiring for Accessories and Options
Inverter
(Note 1)
PR
UVW
RST
P1
P
(Power supply)
Motor
IM
Standard Accessories
Notes: 1. The shown accessories are for use with SUMITOMO 3-phase, 4-pole motors.
2. Select the circuit breaker based on required capacity.
3. Use thicker cables when wiring distance exceeds 20 m.
*The alarm output point should be 0.75 mm
2
.
When using an earth leakage breaker (ELB), select the breaker's trip current from the table below
based on the total wire distance (
R) by summing the distance from the breaker to the inverter and the
inverter to the motor.
Notes: 1. When CV wiring is used in metal conduit, the
leakage current is approximately 30mA/km.
2. Leakage current will increase eightfold with IV type
cable due to higher dielectric constant. In this
case, use ELB with the next higher trip rating.
FunctionName
Input AC reactor for
harmonic suppression/power
smoothing/powerfactor
improvement
This is useful in suppressing harmonics induced on the power supply
lines, or when the main power voltage imbalance exceeds 3%, (and
power source capacity is more than 500kVA), or to smooth out line
fluctuations. It also improves the power factor.
Electrical noise interference may occur on nearby equipment such
as a radio receiver. This magnetic choke filter helps reduce radiated
noise.
This filter reduces the conducted noise in the power supply wiring
between the inverter and the power distribution system. Connect it
to the inverter primary (input side).
This capacitive filter reduces radiated noise from the main power
wires in the inverter input side.
The inductor or choke filter suppresses harmonics generated by the inverter.
The regenerative braking resistor is useful for increasing the
inverter's control torque for high duty-cycle (on-off) applications, and
improving the decelerating capacity.
This filter reduces radiated noise emitted on the inverter output cable
that may interfere with radio or television reception and test
equipment and sensor operation.
Electrical noise interference may occur on nearby equipment such
as a radio receiver. This magnetic choke filter helps reduce radiated
noise.
Install it on the output side to reduce leakage current contributed by
higher harmonics. Contact our company for details.
Radio noise filter
Zero-phase reactor
Input noise filter for
inverter LC filter
Input radio noise filter
(XY filter)
DC reactor
Regenerative braking resistor
HF-320 only
Output noise filter
LC filter
Radio noise filter
Zero-phase reactor
Output AC reactor
R
100m or less
300m or less
600m or less
Trip current (mA)
30
100
200
Inverter model
Rated
input
voltage
Circuit breaker
(made by
Mitsubishi
Electric)
Electromagnetic
contactor
(made by
Fuji Electric)
Cable size
20m
(mm
2
)
200V
400V
SC - 03
SC - 1N
SC - 03
SC - 1N
SC-2N (2SN)
SF3202-A20
SF3202-A40
HF3202-A20
HF3202-A40
NF-30 5A
NF-30 10A
NF-30 20A
NF-30 30A
NF-50 50A
NF-100 60A
NF-30 5A
NF-30 10A
NF-30 20A
NF-30 30A
HF3202-A75
HF3202-1A5
HF3202-2A2
HF3202-3A7
HF3202-5A5
HF3202-7A5
HF3204-A40
HF3204-A75
HF3204-1A5
HF3204-2A2
HF3204-3A7
HF3204-5A5
HF3204-7A5
SF3202-A75
SF3202-1A5
SF3202-2A2
SF3202-3A7
SF3202-5A5
SF3202-7A5
SF3204-A40
SF3204-A75
SF3204-1A5
SF3204-2A2
SF3204-3A7
SF3204-5A5
SF3204-7A5
Zero-phase
reactor
AC
reactor
LC
filter
Radio noise
filter
DC
reactor
LCfilter
Zero-phase reactor
AC reactor
Electromagnetic
contactor
MCB
Applicable Wiring for Accessories and Options
(Note 1) SF-320 Series are not equipped with a PR terminal. Use HF-320 when regenerative braking is required.
SF-320 series HF-320 series
2
3.5
5.5
8
2
3.5
Common