An AC reactor is available for improvement of the power factor
of the inverter, ensuring proper power line impedance, and
control of higher harmonics.
* The AC reactor is for 3-phase input.
Voltage
(V)
Capacity
(kW)
Braking resistor
Part No.
Rated power Resistance
Qty
Thermal
relay set
value (A)
200V
400V
Type of thermal relay: TR-ONH
200 28 26 22 6 53 287 306 4 340
300 44 40 40 10 78 309 335 5 840
400 44 40 40 10 78 385 411 5 1000
750 57 40 40 10 84 355 381 5 1360
100% braking torque: 10 sec 10% ED
Rated
power
(W)
Dimensions
FGHJKLMN
Weight
(g)
200V
Series
400V
Series
Applicable
capacity
(kW)
Part No.
Y220CA
Specification
Current(A)
L(mH)
W DID2H1H2 A B G L T
Weight
(kg)
Insulation
–
0.4 2.1 5.8 053 90 35 30 100 - 50 38 4 300 M4 1.0 B
0.75 4.0 3.1 054 90 35 30 100 - 50 38 4 300 M4 1.1 B
1.5 8.0 1.6 055 90 40 35 100 120 55 48 4 - M4 1.6 B
2.2 11 1.2 056 115 42 37 120 145 55 43 4 - M4 2.1 B
3.7 17 0.7 057 115 42 37 120 145 55 43 4 - M5 2.4 B
5.5 24 0.5 058 155 45 40 150 180 80 50 5 - M5 3.9 F
7.5 33 0.4 059 155 45 40 150 185 80 50 5 - M6 4.4 F
0.4 1.2 22 080 90 35 30 100 - 50 38 4 300 M4 1.0 B
0.75 2.1 12 081 90 35 30 100 - 50 38 4 300 M4 1.1 B
1.5 4.0 6.5 082 90 40 35 100 - 55 48 4 300 M4 1.7 B
2.2 5.5 4.6 083 115 42 37 120 - 55 43 4 300 M4 2.5 B
3.7 9.0 2.9 084 115 42 37 120 145 55 43 4 - M4 2.8 B
5.5 13 2.0 085 155 45 40 150 175 80 50 5 - M4 4.2 B
7.5 17 1.5 086 155 45 40 150 175 80 50 5 - M5 4.4 B
(Note) Models below 200 V class 3.7 kW of SF-320 and HF-320 are subject to the "Guideline for the Suppression of Harmonics in Household and General-Use Equipment"
issued by the Ministry of International Trade and Industry in September 1994. Therefore, it is necessary to install a reactor for inverters to be installed from January 1,
1997 onward to conform to the standards described in these guidelines.
Options for braking resistor•HF-320
AC reactor for power factor improvement and higher harmonics control
A DC reactor is available for improvement of the
power factor of the inverter, ensuring power line
impedance, and control of higher harmonics.
200V
Series
400V
Series
Applicable
capacity
(kW)
Part No.
Y220DA
Specification
Current(A)
L(mH)
W W1 D D1 D2 D3 H H1 H2 G
Connection
terminal
Insulation
Weight
(kg)
0.2 1.0 29.7 032 52 35 40 32 20 22 65 - 300 dia.4 M4 0.3 B
0.4 2.0 14.8 033 52 35 40 32 20 22 75 - 300 dia.4 M4 0.4 B
0.75 3.75 9.72 034 52 35 50 42 25 27 85 - 300 dia.4 M4 0.6 B
1.5 7.5 4.83 035 74 50 45 37 - - 120 145 - dia.5 M5 1.0 B
2.2 11.0 3.41 036 74 50 45 37 - - 120 145 - dia.5 M5 1.1 B
3.7 18.5 2.13 037 90 60 62 52 - - 140 170 - dia.5 M8 2.0 B
5.5 28.0 1.47 038 90 60 62 52 - - 140 170 - dia.5 M5 2.4 B
7.5 38.0 1.11 039 100 80 95 80 - - 140 170 - 5.5✕7 M5 3.5 B
0.4 1.0 59.3 003 52 35 40 32 20 22 75 - 300 dia.4 M4 0.4 B
0.75 1.88 38.9 004 52 35 50 42 25 27 85 - 300 dia.4 M4 0.6 B
1.5 3.75 19.3 005 59 40 60 47 30 35 100 - 300 dia.4 M4 0.9 B
2.2 5.5 13.7 006 74 50 45 37 - - 120 140 - dia.5 M5 1.1 B
3.7 9.25 8.52 007 74 50 70 62 - - 120 145 - dia.5 M5 1.8 B
5.5 14.0 5.87 008 90 60 62 52 - - 140 165 - dia.5 M5 1.5 B
7.5 19.0 4.46 009 100 80 95 80 - - 140 165 - 5.5✕7 M5 3.5 B
(Note) Models below 200 V class 3.7 kW of SF-320 and HF-320 are subject to the "Guideline for the Suppression of Harmonics in Household and General-Use Equipment"
issued by the Ministry of International Trade and Industry in September 1994. Therefore, it is necessary to install a reactor for inverters to be installed from January 1,
1997 onward to conform to the standards described in these guidelines.
DC reactor for power factor improvement and higher harmonics control