6
6. Technical parameter
Model 108023 108024 108025
PERFORMANCE CONDITION: Air 27°C/ Water 27°C/ Humid. 80%
Heating capacity(kW)
7.0 11.0 15.0
COP Range
14.0~7.2 14.0~7.0 15.0~7.0
PERFORMANCE CONDITION: Air 15°C/ Water 26°C/ Humid. 70%
Heating capacity(kW)
5.0 7.7 10.5
COP Range
7.3~4.5 7.3~4.7 7.7~4.9
TECHNICAL SPECIFICATION
Advised pool volume (m
3
) *
15~30 30~55 40~70
Operating air temperature (
°
C)
-12°C~43°C
Power supply
230V 1Ph
Rated input power (kW)
0.14~1.12 0.22~1.64 0.28~2.15
Rated input current (A)
0.61~4.83 0.96~7.13 1.22~9.32
Sound level at 10m dB(A)
16.5~26.0 16.6~27.9 19.3~32
Advised water flux (m³/h)
2~4 3~5 5~7
Water connection (mm)
50
Remarks:
This heat pump is able to perform normal within air temp -12℃~+43℃, efficiency will not be guaranteed out of this
range. Please take into consideration that the pool heat pump performance and parameters are different under
various conditions.
Related parameters are subject to adjustment periodically for technical improvement without further notice. For
details please refer to nameplate.