Sun Gold Power Inc
www.sungoldpower.com
8
protection
released
(Release when charging)
Plug into the charger to activate
power
consumption
mode
3
Overall
overcharge
protection
Overall overcharge warning
voltage
57.6V
Can be set
Overall overcharge protection
voltage
58.4V
Can be set
Overall overcharge protection
delay
1.0S
Can be set
Overall
overvoltage
protection
released
Overall overcharge protection
release voltage
54.1V
Can be set
Capacity release
SOC
96%
Can be set
Discharge release
> 1A
Discharge current > 1A
4
Overall
overdischarge
protection
Overall over-discharge
warning voltage
43.2V
Can be set
After 30
seconds of
over-
discharge
protection, if
it still cannot
recover, it will
enter low
power
consumption
mode
Overall over-discharge
protection voltage
40V
Can be set
Overall over-discharge
protection delay
1.0S
Can be set
Overall over-
discharge
protection
released
Overall over-discharge
protection release voltage
44.8V
Can be set
Release when charging
Plug into the charger to activate
Charging current
limit function
Charging current limit
20A
5
Charge
overcurrent
protection
Charge overcurrent 1 alarm
current
105A
Can be set
Appearing 10
times in a row
will lock the
status and will
no longer
automatically
release
Charge overcurrent 1
protection current
110A
Can be set
Charge overcurrent 1
protection delay
1.0S
Can be set
Charging
overcurrent
1protection
released
Automatic release)
1min
Automatically cancel after 1min
Discharge release
> 1A
Discharge current > 1A
6
Discharge
overcurrent 1
protection
Discharge overcurrent 1
alarm current)
105A
Can be set
Appearing 10
times in a row
will lock the
status and will
no longer
automatically
release
Discharge overcurrent 1
protection current)
110A
Can be set
Discharge overcurrent 1
protection delay
1.0S
Can be set
Discharge
overcurrent 1
protection
released
Automatic release
1min
Automatically cancel after 1min
Charge release
> 1A
Charge current > 1A
7
Discharge
overcurrent 2
Discharge overcurrent 2
protection current
≥120A
Can be set
Appearing 10
times in a row
will lock the
status and will
no longer
automatically
Discharge overcurrent 2
protection delay
100mS
Can be set
Discharge
Automatic release
1min