Natural Gas
Conversion
11
11. Align and connect the knob with gas valve tightly.
12. Connect the thermocouple with gas valve by screwing
the thermocouple nut clockwise by hand until the nut
cannot screw any more, then continue screwing the nut
3/4 circle clockwise using the wrench carefully
and gently.
NOTE: The thermocouple is made of copper,
DO NOT over bend to prevent dysfunctionality
during the assembly.
13. Stick and place the conversion label onto the
propane rating plate.
14. REMINDER: Perform leak test (refer to page 7).
12
13
Hardware Used
Wrench
knob
gas valve
thermocouple nut
gas valve
1-877-387-3639 | Page 11
propane rating plate
conversion label
WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing
property damage, personal injury, or loss of life.
Item Number:
Model No:
Serial No:
Date Code:
DANGER
CARBON MONOXIDE
HAZARD
This appliance can
produce carbon
monoxide which has no
odor. Using it in an
enclosed space can kill
you. Never use this
appliance in an enclosed
space such as a camper,
tent, car or home.
WARNING:
WARNING: Placing the cylinder too close to the appliance might cause the fire hazard or property loss or
even life hazard.
Type of gas: propane
Normal hourly input: 50,000BTU/hr (14.65 kW)
Manifold pressure: 11 inch w.c. (2.74 kPa)
Maximum inlet supply pressure: 13 inch w.c. (3.24 kPa)
Minimum inlet supply pressure: 8 inch w.c. (1.99 kPa)
CAUTION: The gas pressure regulator provided with this appliance must be used.
This regulator is set for an outlet pressure of 11 inches water column.
Minimum Clearance From Unit To Combustible Construction: 72” (182.9cm) from the top,
24” (61cm) from all sides and back.
For Outdoor Use Only. If Stored Indoors, Detach and Leave Cylinder Outdoors.
The gas supply must be turned off at the LP-gas supply cylinder when this appliance is not in use.
Complies with ANS Z21.97-2017 CSA 2.41-2017, Outdoor Decorative Gas Appliance Standards.
Cover must be removed when burner is in operation.
Removal of this marking will void compliance with standard ANS Z21.97-2017 CSA 2.41-2017.
Do not connect to a remote gas supply.
The instruction manual contains important information necessary for the proper assembly and safe use of the appliance.
Read and follow all warnings and instructions before assembling and using the appliance.
Follow all warnings and instructions when using the appliance.
Do not store or use gasoline, or other flammable vapors and liquids, in the vicinity of this or any other appliance.
An LP-cylinder not connected for use shall not be stored in the vicinity of this or any other appliance.
WARNING: Improper
installation, adjustment,
alteration, service or
maintenance can cause
property damage, personal
injury or loss life. Refer to
the owner's information
manual provided with this
appliance. Installation and
service must be performed
by a qulified installer,
service agency, or the gas
supplier.
If instructions or parts are missing. contact with 1-877-387-3639 or email to custserv@jaytrends.com.
CAUTION: This appliance has been converted to use natural gas. Propane orifice dia 2.21 mm,
natural gas orifice dia 4.18 mm.
Rated Heat Input: 50,000BTU/hr (14.65 kW).
Type Gas: Natural gas
Manifold Pressure: 7 inches water column (1.74 kPa).
This appliance was converted on (day-month-year) to
(insert gas type; e.g. Natural or Propane) gas with Kit. No. by
(name and address of organization making this conversion), which accepts the responsibility that this
conversion has been properly made.
Jay Trends Sales
1901 Aut. Transcanadienne,
Dorval, QC., H9P 1J1, Canada