This is Grid Charge, you need select. ʓ
Start =30%---no use, for customization.
A =40A---It indicates the Current that the Grid
charges the Battery.
Grid Charge---The Switch that the Grid charges the
Battery.
Grid Signal---Disable.
Lithium Mode--This is BMS protocol.
Shutdown 10%--It indicates the inverter will shut
down if the SOC below this value.
Low Batt 20% --It indicates the inverter will alarm if
the SOC below this value.
Restart 40% --It indicates the restart level when
inverter shutdown.
This is Battery 4 stages charge voltage. ʒ
This is for professional installers; you can hold
default if you do not know. ʓ
Shutdown 41V--The inverter will shut down if the
Voltage below this value.
Low Batt 45V --The inverter will alarm if the Voltage
below this value.
Restart 52V --Restart level when inverter shutdown.