EasyManua.ls Logo

SunEdison Silvantis P300 - Option A: Metal Lug

SunEdison Silvantis P300
18 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5.3 OPTION A: METAL LUG
SunEdison recommends using a copper or tin plated grounding lug that is rated for outdoor use and uses no smaller than a #12
wire. The use of a copper split bolt connector is authorized for use as well.
Attach the grounding lug to the frame as follows and shown below in Figure 3:
Step 1: Uses stainless steel metric/english set only. The following is the minimum hardware metric (left) and english (right) required
by SunEdison.
Step 2: Place the grounding lug over the grounding hole on the exterior of the module frame.
Step 3: Place a star washer directly between the bottom of the grounding lug and the exterior surface of the frame.
Step 4: Place a bolt through the lug, star washer and frame grounding hole.
Step 5: Secure the lug to the frame using a flat washer, split washer and nut.
Step 6: Torque the bolt stack to approximately 1.5-2.3 N·m (or 1.1-1.7 ft·lbs) to ensure the star washer scratches the anodized
frame.
10 of 17
METRIC SET
- Stainless Steel Bolt M4
- Stainless Steel Nut M4
- Stainless Steel Flat Washer M4
- Stainless Steel Spring Washer M4
- Stainless Steel Lock-Toothed Washer M4
- Stainless Steel Slotted Washer M4
ENGLISH SET
- Stainless Steel Bolt #8-32
- Stainless Steel Nut #8-32
- Stainless Steel Flat Washer #8-32
- Stainless Steel Spring Washer #8-32
- Stainless Steel Lock-Toothed Washer #8-32
- Stainless Steel Slotted Washer #8-32
Figure 3: Grounding Lug Assembly
Installation Manual: SunEdison Silvantis P300 | M330/F330/D330
© Copyright 2014 SunEdison, Inc.