Operating Instructions
DC Servo Barrier Gate S10
SFMCU MicroDrive
V1.0
Question and Answer IconNeed help?

Do you have a question about the SUNFRE S10 and is the answer not in the manual?

SUNFRE S10 Specifications

General IconGeneral
BrandSUNFRE
ModelS10
CategoryAutomatic Barriers
LanguageEnglish

Summary

Technical Data

Mechanical Part Installation and Adjustment

Controller Wiring and Instructions

7.1.1. 220V/110V Power Supply DIP Switch

How to use DIP switches for selecting input voltage (220V/110V) to output 24V DC or 12V DC.

7.1.2. Motor Interface

Describes the connection of the 24V DC brushless/servo motor to the control board.

7.1.3. Power Interface

Explains the power supply outputs for the motor and control unit.

Controller Auto-Detect After Power-On

Boom Horizontal and Vertical Fine Adjustment

Horizontal Adjustment

Instructions for loosening screws and rotating the arm to the mechanical limit for horizontal alignment.

Vertical Adjustment

How to adjust the vertical position using menu settings (DP10) after horizontal alignment.

Working Codes Meanings and Error Code Solutions

No Reaction on Boom

Troubleshooting steps for when the barrier does not respond to UP/DOWN commands.

Partial Closing During Self-Test

Steps to diagnose why the barrier closes partially during the power-on self-test.

Maintenance

Appendix II: Remote Control Coding

Appendix III: Wiring Diagram for R&G Light Interface

Appendix IV: Wiring Diagram for Up and Down Limit Output

Appendix V: System Menu Setting Procedures

Appendix VI: Setting Menu Explanations

LP01: Working Mode

Defines the working mode between continuous testing and normal operation.

LP02: Auto Delay Time Setting

Allows setting the auto-close delay time after the boom is opened.

LP03: RS485 Address

Configuration for the RS485 communication address.

LP04: RS485 Communication Address

Sets the communication address for RS485 devices.

DP01: Max Open Speed Range

Controls the maximum opening speed of the barrier arm.

DP02: Opening Brake Pulse Duration

Adjusts the speed control during opening to the close position.

DP03: Stating Brake Angle of Opening

Sets the angle at which braking initiates during the opening sequence.

DP04: Max Braking Strength When Opening

Adjusts the maximum force applied during braking while opening.

DP05: Max Close Speed Range

Controls the maximum closing speed of the barrier arm.

DP06: Closing Brake Pulse Duration

Adjusts the speed control during closing to the close position.

DP07: Max Braking Strength When Closing

Adjusts the maximum force applied during braking while closing.

DP10: Opening Angle

Sets the desired opening angle for the barrier arm.

DP11: Lowest Running Speed

Defines the final, slower speed as the arm reaches its open or close position.

DP12: First Speed/Max Auto Revers Speed

Sets the initial opening speed and maximum auto-reverse speed.

Appendix VII: Digitron Display Code and Meanings