Parameter SG15RT SG17RT SG20RT
AC connection type Plug and play
Country of manufacture China
* The inverter enters standby state when the input voltage ranges between 1,000 V and
1,100 V. If the maximum DC voltage in the system can exceed 1,000 V, the MC4 connectors
included in the scope of delivery must not be used. In this case MC4-Evo2 connectors must
be used.
** Please note the min. voltage without MPP tracker derating is 303V (+5%) for SG10/15/
20RT and 236V(+5%) for SG5.0/7.0/8.0RT @AC230V 12.5A.
*** The voltage difference between MPPTs should be less than 150 V. The voltage of the
configured string should be higher than the lower limit of the rated MPPT voltage.
**** For inverters without a DC switch, it is necessary to prepare an external DC switch ac-
cording to AS 60947.3.
Parameter SG5.0RT-P2 SG6.0RT-P2
Input (DC)
Recommended max. PV in-
put power
7.5 kWp 9.0 kWp
Max. PV input voltage 1100 V
*
Min. PV input voltage /
Start-up input voltage
180 V / 180 V
Nominal input voltage 600 V
MPP voltage range 160 V–1000 V
MPP voltage range for
rated power
260V-850V
**
320V - 850V
**
No. of independent MPP
inputs
2
No. of of PV strings per
MPPT
1 / 1
Max. PV input current 32 A (16 A / 16 A)
Max. DC short-circuit
current
40 A (20 A / 20 A)
Output (AC)
Nominal AC power (@ 230
V, 50 Hz)
5000 W 6000 W
Max. AC output power 5000 VA for "AU", "BE",
"DE", 5500 VA for others
6000 VA for "AU", "BE",
"DE", 6600 VA for others
Max. AC output current 8.3 A 10 A