EasyManua.ls Logo

Sungrow SG17RT User Manual

Sungrow SG17RT
153 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
SG3.0RT /
SG4.0RT / SG5.0RT / SG6.0RT /
SG7.0RT / SG8.0RT / SG10RT /
SG12RT / SG15RT / SG17RT /
SG20RT /SG5.0RT-P2 / SG6.0RT-P2 /
SG7.0RT-P2 / SG8.0RT-P2 / SG10RT-
P2 / SG12RT-P2 / SG15RT-P2 /
SG17RT-P2 / SG20RT-P23-Phase PV
Grid-Connected InverterUser
ManualSG3.0-20RT_SG5.0-20RT-P2-
UEN-Ver11-202304
User Manual
3-Phase PV Grid-Connected Inverter
SG3.0RT / SG4.0RT / SG5.0RT / SG6.0RT / SG7.0RT /
SG8.0RT / SG10RT / SG12RT / SG15RT / SG17RT /
SG20RT /SG5.0RT-P2 / SG6.0RT-P2 / SG7.0RT-P2 /
SG8.0RT-P2 / SG10RT-P2 / SG12RT-P2 / SG15RT-P2 /
SG17RT-P2 / SG20RT-P2
SG3.0-20RT_SG5.0-20RT-P2-UEN-Ver11-202304

Table of Contents

Other manuals for Sungrow SG17RT

Question and Answer IconNeed help?

Do you have a question about the Sungrow SG17RT and is the answer not in the manual?

Sungrow SG17RT Specifications

General IconGeneral
ModelSG17RT
Max. DC Voltage1100 V
Start Voltage200 V
MPPT Voltage Range200 V - 1000 V
Number of MPPTs2
Number of DC Inputs per MPPT2
AC Voltage Range310 V - 480 V
Rated Grid Frequency50 Hz / 60 Hz
Total Harmonic Distortion< 3%
Power Factor at Rated Power1
Rated Output Power17000 W
Max. AC Apparent Power18700 VA
Rated AC Voltage400 V
Adjustable Power Factor Range0.8 leading ... 0.8 lagging
DC SwitchYes
Protection Class (According to IEC 62103)Class I
Operating Temperature Range-25°C to +60°C

Summary

Safety Instructions

Handling and Installation Safety

Precautions for unpacking, inspection, installation, and operation.

Electrical and Maintenance Safety

Critical safety measures for electrical work and maintenance procedures.

Product Description

Unpacking and Storage

Mechanical Mounting

Electrical Connection

Safety and Overview

Essential safety rules and a general overview of electrical connections.

AC and DC Cable Connections

Step-by-step guides for connecting AC and DC power cables.

Commissioning

Pre-Commissioning and Power-Up

Final checks and the initial procedure for powering on the inverter.

App Setup and Plant Configuration

Installing the app, creating plants, and configuring network settings.

Device Initialization and Grid Parameters

Initializing the device and setting country-specific grid parameters.

iSolarCloud App Management

System Decommissioning

Disconnecting Inverter

Steps to safely disconnect the inverter from AC and DC power sources.

Troubleshooting and Maintenance

Troubleshooting Guide

Identifies common faults and provides corrective measures for resolution.

Related product manuals