SunPower Solar Monitor Owner’s Guide
4 975-0294-01-01
Choosing a Location
Choose a location that is easily accessible. The monitor
should be mounted where you can have unobstructed access
to the screen and buttons.
The location must be indoors, dry, and free from corrosive or
explosive fumes.
Materials and Tools Required
You will need these materials and tools to complete the
installation:
mounting plate or bracket (supplied)
four #6 screws (supplied)
Phillips screwdriver
jigsaw or small keyhole saw
cable bushing for 1-inch conduit hole
cable clamps or hardware fasteners
Network cables or equivalent (CAT 5 cable with RJ-45
connectors wired to T568A standard)
Male network terminator (supplied)
The total length of the network, including all connected
inverters and monitors, cannot exceed 130 feet (40 meters).
The network layout is a series configuration, with
components connected by a single cable and terminated with
a network terminator at each end of the network. See Figure
3.
WARNING: Explosion hazard
The monitor is not Ignition Protected. Do not install in areas
requiring Ignition-Protected equipment, such as areas containing
gasoline engines, tanks, or fuel-line fittings.