EasyManua.ls Logo

SunStar SC-700A - Lubrication System Setup and Maintenance; Drive Belt Tension Adjustment

SunStar SC-700A
23 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
11
2) Lubrication
(1) Installing Magnetic Chip Remover
A. Attach the magnetic chip remover that is in the
accessory box to the oil pump inside the bed.
(See Fig. 2)
※ Do not use the magnet for other purposes. Use of the
sewing machine without the magnet may cause
malfunction and has a bearing on the machine’s
durability.
[Fig.2]
Magnet
Oil pump
(2) Lubricating the oil fan
A. Fill the lubricant up to the “HIGH”mark. (See
Fig.3.)
B. The lubricant must be SUNSTAR’s oil provided
exclusively for industrial sewing machines or
SHELL’s Tellus C10.
C. If the oil in use is down to the “LOW”mark, fill in
to “HIGH”immediately.
D. Once every two weeks is deemed the appropriate
interval for oil refills.
3) Belt Tension Adjustment
Sufficient loosening of the fixed nuts①, ② after motor③
installation would create tension to the belt④. Tighten the
fixed nut① first and then tighten the fixed nut② to an
unmovable position. (See Fig. 4)
[Fig.3]
[Fig.4]