100
1)
Understanding the Function of Machine Test : The order can be different depending on SPS/A/B/C-Series.
1-1) Encoder Test
It is a test if input of encoder and synchronizer is proper along with the present position of needle bar.
A. Press MODE key.
B. After moving to “4. Machine Test” by using
direction keys , press ENTER key.
C. Press ENTER key. Upper feed plate comes
to descend, and moves to origin. At this time, if
you slowly turn the upper shaft pulley
manually, the pulse value of encoder, relative
position of the upper shaft synchronizer sensor,
and turning times of upper shaft will be marked.
D.
If you want to finish encoder test, press ESC key.
If you want to finish test menu, press ESC also.
E. Back to the general sewing mode by pressing
ESC key.
A. Press MODE key.
B. After moving to “4. Machine Test” by using
direction keys , press ENTER key.
C. After moving to “1. XY-Main Test”by using
direction keys , press ENTER key. The
upper feed plate descends and moves to the
origin.
<< Main Menu >>
4. Machine Test
5. Pattern List
6. EMB Call
<< Test Menu >>
0.Encoder Test
1.XY-Main Test
2.MainMotorTest
Enc Val = 00000
Pos Val = 00000
Syn Num = 00000
PulySize = 01150
<< Main Menu >>
4. Machine Test
5. Pattern List
6. EMB Call
<< Test Menu >>
1.XY-Main Test
2.MainMotorTest
3.InterruptTest
1-2) Step Motor-Main Shaft Motor Test (X-Y Main Test)
It is a test if a step motor and main shaft motor works properly at the same time.