109
C. Move to by using
keys and press key.
ENTER
direction
14.Encoder1 Test
D. Press key. Upper feed plate will
descend and go to the original point. At this time,
turning upper shaft pulley by hand will indicate
pulse value of lower encoder, distance from synch
sensor, and rotation number.
ENTER
Enc Val = 00000
Pos Val = 00000
Syn Num = 00000
E. To end lower shaft encoder test, press key. To end test menu, press key.
ESCESC
F. Return to the initial screen by pressing key.
ESC
<< Test Menu >>
14.Encoder1 Test
15.Solenoid Test
16.Output4 Test
C. Move to ”by pressing
keys and press key.
ENTER
direction
15.Solenoid Test
1-16) Solenoid Test
This is used to check whether or not Solenoid is working properly.
<< Main Menu >>
4. Machine Test
5. Pattern List
6. EMB Call
A. Press key.
MODE
<< Test Menu >>
15.Solenoid Test
16.Output4 Test
17.Output5 Test
B. Move to “4. Machine Test” by pressing
keys and press key.
ENTER
direction
1-15) Lower Shaft Encoder Test (Encoder1 Test) [Only applied for SPS/C-Series]
This is used to check whether or not Input of Lower Shaft Encoder and Synch is normal and test the
current position of needle bar.
<< Main Menu >>
4. Machine Test
5. Pattern List
6. EMB Call
A. Press key.
MODE
B. Move to “4 Machine Test” by using
keys and press key.
ENTER
direction