E. Press key to end solenoid test. Press key to end Test Menu.
ESCESC
F. Press key to return to initial page.
ESC
C. Move to ”by pressing
keys and press key.
ENTER
direction
16.Output4 Test
D. Repeat turning on and off relevant air pressure port
by pressing the number of air pressure port to be
tested.
1. : Presser Foot
2. : Upper Feed Plate
3. : Thread Trimming
4. : Thread Holder
5. : Wiper
6. : Detachable Left Upper Feed Plate
7. : Two-Step Stroke
8. : Reverse Device
RVA
TSA
FFLA
WPA
THA
TTA
FFA
PFA
1 PFA Of 2FFA Of
3 TTA Of 4THA Of
5 WPA Of 6FFLA Of
7 TSA Of 8RVA Of
E. To end air pressure port test, press key. To end test menu, press key.
ESCESC
F. Return to the initial screen by pressing key.
ESC
1-17) Output 4 Test [only applied for SPS/C-Series]
This function can be used to check whether or not air pressure devices are working properly.
<< Main Menu >>
4. Machine Test
5. Pattern List
6. EMB Call
A. Press key.
MODE
<< Test Menu >>
16.Output4 Test
17.Output5 Test
18.Output6 Test
B. Move to “4. Machine Test” by pressing
keys and press key.
ENTER
direction
D. Repeat turning on and off relevant solenoid by
pressing the number of solenoid to be tested.
1. : Presser Foot
2. : Upper feed plate
3. : Trimming
4. : Thread Holder
5. : Wiper
6. : Detachable left upper feed plate
7. : Two step Stroke
8. : Reverse device
RV
TS
FFL
WP
TH
TT
FF
PF
1 PF Of 2FF Of
3 TT Of 4TH Of
5 WP Of 6FFL Of
7 TS Of 8RV Of