112
C. Move to “ ”by pressing
keys and press key.
ENTER
direction
22.XY-Jog Test
D. If you press keys , the position
shows coordinates of X and Y shaft and present
position among 4 section moving to a step each.
direction
X-Y jogging Test
ESC to Exit
X:0000 Y:0000
Xsen:1 Ysen:1
E. To end manual operation of step motor, press key. To end test menu, press key.
ESCESC
F. Return to the initial screen by pressing key.
ESC
<< Test Menu >>
22.XY-Jog Test
23.Origin Test
24.Jump Test
C. Move to “ ” by using
keys and press key.
ENTER
direction
23.Origin Test
1-21) Origin Test
This is used to check whether or not movement of original point is working properly.
<< Main Menu >>
4. Machine Test
5. Pattern List
6. EMB Call
A. Press key.
MODE
<< Test Menu >>
23.Origin Test
24.Jump Test
25.MotorType Test
B. Move to “4 Machine Test” by using
keys and press key.
ENTER
direction
1-20) Manual Operation Test of Step Motor (XY Jog Test)
This function can be used to manually test XY step motor.
<< Main Menu >>
4. Machine Test
5. Pattern List
6. EMB Call
A. Press key.
MODE
B. Move to “4. Machine Test”by pressing
keys and press key.
ENTER
direction