Connect 1625-15Plug of the auto call function cable to the sensor input connector on the rear PC box. Connect XHP-9
to CN16 on the I/O board.
See 'Description on connector and jumper pin location' for the connector locations on the I/O board.
See the cable specifications for cable connector.
A total of 7 adjacent sensor cables are used. Please request the desired number of the cables depending on user
need.
Cable name Product No. Cable connecting location
(SPS/C-5050,8050) Auto call function
cable
Adjacent sensor cable
CA-003044,00
CA-002857,00
Connector on the rear PC box side for sensor input
CN16 on the I/O board
SMR-03V-N of the auto call function cable
Cables connected by user
Cable signal input information
1 +5V or +24V BR6
SEN_0 2 SEN_0
3 GND
1 +5V or +24V BR7
SEN_1 2 SEN_1
3 GND
1 +5V or +24V BR7
SEN_2 2 SEN_2
3 GND
1 +5V or +24V BR8
CLAMP 2 Clamp driving signal
3 GND
1 +5V or +24V BR8
EM-STOP 2 Emergency stop signal
3 GND
1 +5V or +24V BR8
START 2 Signal line for sewing start signal
3 GND
1 +5V or +24V BR8
ENTER 2 Signal line for ready signal
3 GND
Signal name
Connector pin number
(SMR-03V-N)
Description
Jumper pin for voltage
change