48,&.6(77,1*)81&7,21
11
7DEOHRITXLFNVHWWLQJQXPEHUV!
Simply by selecting a setting number, output operation, emission
amount, timer, and emission frequency can be set.
)RUWKHVHWWLQJQXPEHUVUHIHUWR7DEOHRITXLFNVHWWLQJQXPEHUV!.
Ɣ
Ɣ
<When in RUN mode>
Press for 2 sec.
(Note 1)
: Select a quick setting number
(Quick setting)
: Select emission frequency
(Emission frequency setting)
(Note 1)
Automatic
Notes: 1) &DQFHOODWLRQLVSRVVLEOHZKHQSUHVVLQJ02'(NH\IRUVHFRUPRUHEHIRUH
¿QDOL]LQJWKHQUHWXUQVWR581PRGH
.
2)
When the present setting is out of the quick setting range, ³ ´ is shown.
When ³
´
is selected, the set content is not changed.
No.
Output
operation
Emission amount
setting
Timer
-00- '21 2))
non
-01- '21 ON
non
-02- '21 2))
ofd 10ms
-03- '21 ON
ofd 10ms
-04- '21 2))
ofd 40ms
'21 ON
ofd 40ms
-06- '21 2))
ond 10ms
'21 ON
ond 10ms
-08- '21 2))
ond 40ms
-09- '21 ON
ond 40ms
No.
Output
operation
Emission amount
setting
Timer
-10- L-ON ON
ond 40ms
-11- L-ON 2))
ond 40ms
-12- L-ON ON
ond 10ms
-13- L-ON 2))
ond 10ms
-14- L-ON ON
ofd 40ms
L-ON 2))
ofd 40ms
-16- L-ON ON
ofd 10ms
L-ON 2))
ofd 10ms
-18- L-ON ON
non
-19- L-ON 2))
non
6(77,1*&23<)81&7,21
7KLVFDQFRS\WKHVHWWLQJVRIWKHPDVWHUVLGHDPSOL¿HUWRWKHVODYHVLGH
DPSOL¿HU
Ɣ
Be sure to use the setting copy function between the identical models.
This function cannot be used between different models.
Only one sensor can be connected on slave side with a master side
sensor for the setting copy function.
Threshold value, output operation setting, timer operation setting, timer
VHWWLQJHPLVVLRQDPRXQW VHWWLQJVKLIW VHWWLQJH[WHUQDO LQSXWVHWWLQJ
threshold value-storing setting, ECO setting, inverting digital display set-
ting, and threshold value margin setting can be copied.
Ɣ
Ɣ
Ɣ
6HWWLQJSURFHGXUHV!
Master side amplifier
Slave side amplifier
(Brown) V
(Brown) V
(Blue) 0V
(Blue) 0V
(White) External input
(White) External input
(Black) Input
(Black) Input
Color code of cable with connector
Power supply
7RFDQFHOWKHVHWWLQJFRS\PRGHRIWKHPDVWHUVLGHDPSOL¿HU!
:KLOHWKHVODYHVLGHDPSOL¿HULVGLVFRQQHFWHGWXUQRQWKHSRZHURIWKH
PDVWHUVLGHDPSOL¿HU
3UHVV02'(NH\IRUDSSUR[VHF
4. Turn on the master side amplifier and the slave side amplifier at the
same time. (Note)
³
´LVVKRZQRQWKHJUHHQGLJLWDOGLVSOD\RIWKHPDVWHUVLGHDPSOL¿HU
and 4-digit code is shown on the red digital display of it, then the copying
starts.
:KHQWKHFRS\LQJLV FRPSOHWHG³
´LV VKRZQRQ WKHJUHHQ GLJLWDO
GLVSOD\RIWKHVODYHVLGHDPSOL¿HUZKLOHWKHGLJLWFRGHWKHVDPHFRGH
DVWKHPDVWHUVLGHDPSOL¿HULVVKRZQRQWKHUHGGLJLWDOGLVSOD\RILW
7XUQRIIWKHSRZHURIWKHPDVWHUVLGHDPSOL¿HUDQGWKHVODYHVLGHDPSOL-
¿HUDQGGLVFRQQHFWWKHZLUH
,IFRS\LQJWKHVHWWLQJVWRDQRWKHUDPSOL¿HUUHSHDWHGO\IROORZWKHVWHSV
WR
Note: Take care that if the power is not turned on at the same time, the setting con-
tents may not be copied.
6HWWKHVHWWLQJFRS\PRGHRIWKHPDVWHUVLGHDPSOL¿HUWR³&RS\VHQGLQJ
21´DQGSUHVV02'(NH\VR
WKDW³
´LVVKRZQRQWKHGLJLWDO
GLVSOD\DQGWKH VHQVRULV LQFRS\ UHDG\VWDWH)RUWKHVHWWLQJPHWKRG
UHIHUWR6HWWLQJFRS\PRGH!LQ³
35202'(´
7XUQRIIWKHPDVWHUVLGHDPSOL¿HU
&RQQHFWWKHPDVWHUVLGHDPSOL¿HUZLWKWKHVODYHVLGHDPSOL¿HUDVVKRZQ
below.
(;7(51$/,13876(77,1*
9
Emisson halt
(Note 1)
External input signal
Limit
teaching
2-level
teaching
Full-auto
teaching
(Note 4)
ECO mode
High
Low
Emission halt
Teaching in progress
Normal operation
Normal operation
Normal operation
ECO in progress
Emission
Teaching in progress
20ms
25ms or more
20ms or more
20ms 20ms
20ms 20ms
20ms
20ms 20ms
20ms 20ms 20ms
(Note 3)
20ms
20ms 20ms
NPN output
type: Low
NPN output
type: High
Teaching in progress
Normal operation
20ms 20ms
First point
Second point
Sampling in
progress
(Note 2)
(Note 5)
(Note 2)
1RWHV2XWSXWPD\WXUQ212))ZKHQHPLVVLRQLVKDOWHGRULVUHOHDVHGGHSHQGLQJ
on setting of threshold value.
2) When emission starts, output operation will be undetermined only during the
response time.
If the output signal is received by something such as a PLC, set the timer to
DYDOXHRIPVDPSOL¿HUUHVSRQVHWLPHRUJUHDWHU
([DPSOH )RUWKH);ƑZLWKHPLVVLRQIUHTXHQF\UHVSRQVHWLPHV
or less)
7LPHUSHULRGPVPVV PV
3) After teaching is complete, output operation will be undetermined only during
the response time. If the output signal is received by something such as a
3/&VHWWKHWLPHUWRWKHDPSOL¿HUUHVSRQVHWLPHRUJUHDWHU
The threshold value will be set based on the incident light intensity at the in-
VWDQWZKHQWHDFKLQJLVYHUL¿HG
0RYH WKH VHQVLQJREMHFWSDVWRQFHGXULQJ WKH WLPHWKDWWKHH[WHUQDOLQSXW
signal is being input.
$IWHUWHDFKLQJLVFRPSOHWHRXWSXWRSHUDWLRQZLOOEHXQGHWHUPLQHGRQO\GXULQJ
the response time. If the output signal is received by something such as a
3/&VHWWKHWLPHUWRWKHDPSOL¿HUUHVSRQVHWLPHRUJUHDWHU
$OHUWRXWSXWRIH[WHUQDOLQSXWWHDFKLQJ!
:KHQFRQGXFWLQJOLPLWWHDFKLQJRUSRLQWWHDFKLQJE\H[WHUQDOLQSXWLI
WKHDOHUWRXWSXWRIH[WHUQDOLQSXWWHDFKLQJ³
´LVVHWLQWKHWKUHVK-
ROGYDOXHPDUJLQVHWWLQJPRGHRXWSXWWXUQV212))HYHU\PVLQ
case the rate of reference incident light intensity and threshold value
DIWHUWHDFKLQJLVRUPRUHRULQFDVHLWLVOHVVWKDQKDOIRIWKHVKLIW
amount.
)RUWKHVHWWLQJPHWKRGUHIHU WR7KUHVKROGYDOXHPDUJLQVHWWLQJ
PRGH! under ³
35202'(´
Ɣ
Output operation
when selecting
alert output of
external input
teaching
“ ”
Output operation
when selecting
alert output of
external input
teaching
“ ”
External
input signal
Limit
teaching
Teaching in progress
Normal operation
ON
OFF
20ms
(Note 1) (Note 1)
(Note 2)
20ms
NPN output
type: Low
High
Low
NPN output
type: High
100ms
2-level
teaching
Teaching in progress
ON
OFF
Normal operation
20ms 20ms
First point
Second point
25ms or more
20ms or more
䧎
100ms
100ms
䧎
100ms
100ms
䧎
100ms
1RWHV,Q FDVH WKHPDUJLQLVQRJRRG RXWSXW WXUQV212))HYHU\PV GXULQJ
WKHWLPHWKDWWKHH[WHUQDOLQSXWVLJQDOLVEHLQJLQSXWDIWHUWHDFKLQJ
2)
,QFDVHWKHPDUJLQLVQRJRRGRXWSXWWXUQV212))HYHU\PVGXULQJWKH
WLPHWKDWWKHH[WHUQDOLQSXWVLJQDOLVEHLQJLQSXWDIWHUWKHVHFRQGWHDFKLQJ
:KHQVHOHFWLQJHPLVVLRQ KDOWLQ WKHH[WHUQDO LQSXWVHWWLQJPRGHDQGUH-
FHLYLQJWKHVLJQDOH[WHUQDOO\³
´LVLQGLFDWHGRQWKHUHGGLJLWDOGLVSOD\
:KHQVHOHFWLQJ(&2LQWKHH[WHUQDOLQSXWVHWWLQJPRGHNH\RSHUDWLRQRQ
WKHPDLQERG\LVLQYDOLGGXULQJH[WHUQDOLQSXW
:KHQVHOHFWLQJSRLQWWHDFKLQJLQWKHH[WHUQDOLQSXWVHWWLQJPRGH³ ´
is indicated on the green digital display after inputting the first point.
)RUWKHVHWWLQJRIH[WHUQDOLQSXWUHIHUWR³ 35202'(´
Ɣ
Ɣ
Ɣ
Ɣ
7LPHFKDUWZKHQVHWWLQJH[WHUQDOLQSXW!