- Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
- WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use
any phone in your building.
Leave the building immediately.
Immediately call your gas supplier from a neigh-
bor’s phone. Follow the gas supplier’s instruc-
tions.
If you cannot reach your gas supplier, call the
fire department.
- Installation and service must be performed by
a qualified installer, service agency or the gas
supplier.
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could
result in serious injury, death, or property damage.
AVERTISSEMENT:
RISQUED’INDENDIE OU D’EXPLOSION
Le non-respect Des avertissements de sécurité
pourrait d’entraîner des blessures graves, la mort
ou des dommages matériels.
- Ne pas entreposer ni utilizer d’essence ni d’autres
vapeurs ou liquides inflammables dans le voisinage
de cet appareil ou de tout autre appareil.
- QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ:
• Ne pas tenter d’allumer d’appareil.
Ne touchez à aucan interrupteur. Ne pas vous servir
des téléphones se trouvant dans le bâtiment
vous trouvez.
Sortez immédiatement de bâtiment.
Appelez immédiatement votre fournisseur de
gaz depuis un voisin. Suivez les instructions du
fournisseur.
Si vous ne pouvez rejoindre le fournisseur de gaz,
appelez le service des incindies.
- L’installation et l’entretien doivent être assurés par
un installateur ou un service d’entretien qualifié
ou par le fournisseur de gaz.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future
reference.
Installateur : Laissez cette notice avec l’appareil.
Consommateur : Conservez cette notice pour
consultation ultérieure.
This appliance may be installed in an aftermarket permanently located, manufactured home (USA only)
or mobile home, where not prohibited by local codes. This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certified kit
is used.
Cet appareil peut installé dans une maison préfabriquée (mobile) déjà installée à demeure, si les réglements
locaux le permettent. Ce appareil doit être utilisé uniquement avec le type de gaz indiqué sure la plaque
signalétique. Cet appareil ne peut être converti à d’autres gaz, sauf si une trousse de conversion est utilsée.
Installation and Operation Instructions
Models
CU
S
Report No. F19-008
Ce manuel est disponible en francais, simplement
en faire la demande. Numéro de la pièce 900994-02
P/N 900994-00 REV. K 07/2021
DRL2000 & DRL3500 Series Direct-Vent Gas Fireplaces
P900994-00
DRL2035TEN
DRL2045TEN
DRL2055TEN
DRL3535TEN
DRL3545TEN
DRL3555TEN
f i r e - p a r t s . c o m

Table of Contents

Questions and Answers

  • K
    kristen41Aug 10, 2025
    What to do if Superior Fireplaces DRL2045TEN won't turn on?
    • A
      Alexis Bridges DDSAug 10, 2025
      If nothing happens when you turn your Superior Fireplaces Indoor Fireplace ON/OFF, here are a few things you can check: * Ensure the wall switch plate is set to REMOTE. * Try operating the fireplace from the wall plate switch. * Replace the remote and/or wall switch batteries. * Verify that gas is reaching the fireplace by checking the gas supply and gas shutoff valves. * Check/replace backup batteries behind the wall plate. * Replace the unit battery backup. * Check the building circuit breakers to ensure power is ON to the fireplace.
  • C
    Claire McintoshAug 17, 2025
    Why does my Superior Fireplaces DRL2045TEN burner turn on and then off?
    • A
      Alyssa GarciaAug 17, 2025
      If the main burner on your Superior Fireplaces Indoor Fireplace comes on but then goes out, the following troubleshooting steps may help: 1. Switch the CPI/IPI switch to pilot ON mode and wait two minutes before relighting. 2. Verify that gas is reaching the fireplace by checking the gas supply and gas shutoff valves. 3. Inspect the control compartment for any obviously loose wiring. If needed, call a service technician. If these steps don't resolve the issue, further assistance from a qualified service technician may be required to address potential issues such as the pilot flame not engulfing the sensor or an obstructed vent system.
  • G
    ginawashingtonAug 25, 2025
    What to do if Superior Fireplaces DRL2045TEN igniter sparks but burner doesn't light?
    • D
      Donald HarperAug 26, 2025
      If the main burner does not light but the igniter is sparking on your Superior Fireplaces Indoor Fireplace, there are several possible causes: * Make sure that gas is reaching the fireplace by checking the gas supply and gas shutoff valves. * Check the control compartment for any obviously loose wiring. If necessary, call a service technician. * Check for loose wires to the ignition module. If necessary, call a service technician. * Purge the gas line of air. If required, call a service technician. * Replace the unit battery backup.
  • S
    Sara AdamsSep 2, 2025
    Why is the flame poor or blue on my Superior Fireplaces DRL2045TEN Indoor Fireplace?
    • E
      Eric BryantSep 2, 2025
      Poor flame or a blue flame in your Superior Fireplaces Indoor Fireplace can be caused by a door seal that is not properly aligned, leading to gaps and air leaks. To fix this, remove and realign the door so the gasket seal is fully engaged around the door frame.

Summary

Critical Safety Information

Safe Operation: Glass Integrity

Do not operate with damaged or missing glass front.

Appliance Safety: Water Exposure

Do not operate if submerged; call qualified technician for inspection.

Surface Temperature Safety

Alert users to high surface temperatures to prevent burns and clothing ignition.

Child Supervision Safety

Supervise young children closely around the operating appliance to prevent accidental burns.

Qualified Service Personnel Requirement

Installation and repair must be performed by qualified service personnel.

Installation & Service Notices

Installation Hazard Warning

Improper installation, adjustment, or service can cause injury or property damage.

Carbon Monoxide Hazard

Early signs of CO poisoning are flu-like; seek fresh air and service if symptoms occur.

Installation Overview

Fireplace Operation Guidelines

Child Supervision During Operation

Supervise children closely to prevent burns from hot surfaces.

Operation Carbon Monoxide Hazard

Signs are flu-like; seek fresh air and service if symptoms occur.