English
23
SHUTDOWN
Action Description Anzeige auf dem Display
F
uel loading will stop, while the cooling fan and
the extractor fan will continue to run for anoth-
er ten minutes until the stove has cooled
O
K
SET
GRUPPO PIAZZETTA
1
2
3
4
5
6
AL. F
SET
AL. C
Do not unplug the stove from the power supply at this stage as this could cause internal problems and compromise future
startup operations.
D
T2040009-00
Hold the ON/OFF key
down for several sec-
onds
6.4 Remote control - Fig. 30
The stove’s control panel has been set to receive some commands
by remote control.
• Startup/Shutdown: by pressing the two ‘+’ keys simultaneously
the stove can be turned on or off.
• Power level: when operating normally, pressing the ‘+’ and ‘-’ keys
above the flame symbol will select one the stove’s four power lev-
els.
• Temperature: when operating normally, pressing the ‘+’ and ‘-’
keys above the thermometer symbol will select the desired room
temperature (10-30ºC).
6.5 Timer
The timer allows the user to programme the stove to start up and
shut down automatically without any manual intervention.
A maximum of two cycles can be programmed:
For example: Cycle one: from 6 until 9 am
Cycle two: from 8.30 until 11 pm
The two cycles can be activated or deactivated on each of the days
of the week (eg, if you want the stove to be lit fr
om 6 until 9 on
Monday, Tuesday but not on Wednesday, and so on…)
Programming codes and relative functions
During programming certain codes will appear in the lower part of
the display
. These r
epr
esent the functions described below:
DT2030079-00
F
ig. 30
Code FUNCTION
01u
Sets the current day of the week.
02u
Sets the cur
r
ent time.
03u
Activates/deactivates the alar
m during operation.
Activates/deactivates the display of time and temper-
ature.
05u
Activates/deactivates timer programming mode.
06u
Inputs star
tup time for first operating cycle.
07u
Inputs shutdown time for first operating cycle.
08u
Selects the days of the week (shown as: Lu, Ma, Me,… Do) on
which first cycle will be activated ON or deactivated OFF
09u
Selects the desired temperature
Selects the power level: 1 minimum, 4 maximum
10u
Inputs the ignition time in the second operating cycle
11u
Inputs shutdown time in the second operating cycle
12u
Selects the days of the week (shown as: Lu, Ma, Me,… Do) on
which first cycle will be activated ON or deactivated OFF
13u
Selects the desired temperature
Selects the power level: 1 minimum, 4 maximum