Chapter 4: BIOS
99
MECI (Multiple Event Count Increment)
Enter the increment value for the multiple event counter. Enter a number between 1 to 255.
The default setting is 1.
METW (Multiple Event Count Time Window)
Use this feature to specify how long (in minutes) the multiple event counter should wait before
generating a new event log. Enter a number between 0 to 99. The default setting is 60.
Note: Please reboot the system for the changes to take effect.
Custom Options
Log OEM Codes
Select Enabled to log EFI Status Codes as OEM Codes. The options are Enabled and
Disabled.
Convert OEM Codes
Select Enabled to convert EFI Status Codes to that of standard SMBIOS Type. The options
are Disabled and Enabled.
View SMBIOS Event Log
This item allows the user to view the event in the system event log. Select this feature and
press <Enter> to view the status of an event in the log. The following categories are displayed:
Date/Time/Error Code/Severity