SMBIOS Event Log Standard Settings
Log System Boot Event
This option toggles the System Boot Event logging to enabled or disabled. The options are
Disabled and Enabled.
MECI
The Multiple Event Count Increment (MECI) counter counts the number of occurrences that
a duplicate event must happen before the MECI counter is incremented. This is a numeric
value. The default value is 1.
METW
The Multiple Event Time Window (METW) denes the number of minutes that must pass
between duplicate log events before MECI is incremented. This is in minutes, from 0 to 99.
The default value is 60.
Note: After making changes on a setting, reboot the system for the changes to take
e󰀨ect.
View SMBIOS Event Log
Select this submenu and press enter to see the contents of the SMBIOS event log. The
following categories is displayed: Date/Time/Error Codes/Severity.