6.4 F2 System Calibration6.4 F2 System Calibration
6.4.1 Zero Calibration6.4.1 Zero Calibration
Keep the belt Keep the belt
weigher running without load weigher running without load
for correcting Zero for correcting Zero
VV
alue.alue.
MENUMENU
: Exit: Exit
ENTENT
: Save: Save
MM
New New
Zero: Zero:
1440014400
E%: -1.00%E%: -1.00%
1 Zero Cal.1 Zero Cal.
Old Old
Zero: Zero:
1500015000
00
55
[R][R]
R: 1-99R: 1-99
P110 Cal. RevsP110 Cal. Revs
Remainder length of a Remainder length of a
revolutionrevolution
::
Display Flow, Load or AD ValueDisplay Flow, Load or AD Value
Main Display InterfaceMain Display Interface
MENUMENU
++
: F2 Calibration: F2 Calibration
ENTENT
++
: 1 Zero Cal.: 1 Zero Cal.
ENTENT
MM
ENTENT
Flow: 0.0t/hFlow: 0.0t/h
01R 10.00m01R 10.00m
1 Zero Cal.1 Zero Cal.
Zero: 14400Zero: 14400
Revolution CountRevolution Count
After running Calibration After running Calibration
Revolutions:Revolutions:
E% = (ER / Max. AD Value) × 100%E% = (ER / Max. AD Value) × 100%
ER = New Zero Value - Old Zero ValueER = New Zero Value - Old Zero Value
Max. AD Value = 60000Max. AD Value = 60000