2023-11-30 53 2301122
Ballast
The first section of this page controls how quickly the
ballast fills and drains. Use the and + buttons to
establish the minutes and seconds for the Port, Center
and Starboard ballast bags.
The second section of this page concerns the
SmartPlate:
Crossover Point: Establish the percent of set speed at
which the SmartPlate activates to the position set in the
rider profile.
SmartPlate Down: Establish the percentage at which the
SmartPlate will be tilted down when the speed is less than
the crossover point.
SmartPlate Up: Establish the percentage at which the
SmartPlate will be tilted up when the speed is greater than
15 mph and the cruise is off.
Supra Launch System: enable (Dynamic or Fixed) or disable (Off) this system to be used as a
launch aid when Swell Surf is turned off.