6-28
UNIT
end
oil
clearance
the clearance as follows.
the surface of the the conrod cap and the
crank pin.
2.
Place a piece the piastigauge
on
the crank parallel to
the crankshaft, avoiding the
oil hole.
09900-22301: Plastigauge
3.
Install the conrod and the conrod cap
to
the crank
4.
Install the two conrod bolts and bolts to the spec-
ified two steps.
NOTE:
Do
not
rotate the conrad with the plastigauge
in
place.
Conrod
bolt:
st
step
2nd
step
N·m (0.35 kg-m, 2.5
7
N·m (0.7 kg-m,
5.0
5.
Remove the conrod and the conrod cap from the crank
6.
the scale
on
the plastigauge envelop, measure the
with the widest
Conrod
big
end
clearance:
0.15-
0.035
mm
-0.0014
0.080
mm
the measurement exceeds the service limit replace the conrad
and/or crankshaft.
end
inside
diameter:
1
5-19.025
mm
-0.7490
run
out
Measure the crankshaft runout as shown
in
the figure.
09900-20602: Dial
run out:
Service
limit:
0.05 mm
the measurement exceeds the service
shaft.
replace the crank-