Describes the microprocessor-based, integrated control system managing unit functions.
Explains the different heat exchanger types (RX, PX, CX) used in GOLD units.
Outlines components of the GOLD RX unit with a rotary heat exchanger.
Details components of the GOLD PX unit with a plate heat exchanger.
Explains components of the GOLD CX unit with coil heat exchangers.
Location and use of safety isolating switches for different unit sizes and types.
Highlights dangers from rotating parts and the need for caution during operation.
Describes safety guards and their importance for protection against moving parts.
Outlines the general sequence for commissioning air handling units.
Step-by-step guide for adjusting air devices and ductwork for optimal airflow.
Explains how to adjust pressure balance in extract air path for proper heat exchanger function.
Details how to use adjustment plates and pressure readings to ensure correct leakage direction.
General description of the hand-held terminal, its components, and connectivity.
How to start, stop, or switch between manual and automatic operation.
Basic temperature settings that can be preset at installation and read/set at user level.
Detailed settings for ERS Regulation, Supply Air Regulation, and Extract Air Regulation.
Details settings for low speed, high speed, max speed, and min/max speed.
Procedure for calibrating filters after installation or replacement.
Overview of the menu structure available at the Installation Level.
Basic temperature functions set at INSTALLATION and read/set at USER LEVEL.
Options for ERS, Supply Air, and Extract Air temperature regulation.
Explains ERS regulation for supply air temp based on extract air temp.
Maintains constant supply air temperature, often requiring reheating/cooling coils.
Maintains constant extract air temperature by regulating supply air temp.
Controls an additional temperature zone via the ventilation system.
Adjusts supply or extract air setpoints based on outdoor temperature.
Utilizes night cooling to reduce building structure temperature, saving energy.
Heats premises during scheduled stops using an external room sensor.
Heats premises before switch-in time using air recirculation.
Allows changing supply/extract air setpoints via external 0-10VDC signal.
Provides extra control functions via 0-10V signal for heating or cooling sources.
Uses external sensors for extract air/room or outdoor temperature readings.
Basic flow/pressure functions are set at INSTALLATION and read/set at USER LEVEL.
Allows individual selection of regulation type for supply and extract air fans.
Maintains constant airflow by automatically regulating fan speed.
Varies airflow to maintain constant pressure in the ducting (VAV).
Regulates airflow based on external sensor signals (e.g., CO2).
Allows one fan to follow the airflow of another controlling fan.
Reduces airflow in wintertime based on outdoor temperature.
Details cooling regulation methods like CoolDX Economy, Comfort, and Stepless.