Poor detection of
upper thread
Bad jump
Bad stitch quality
Failure of thread detecting
roller
Poor connection and bad
quality of tension adjusting
plate
Bad solenoid and solenoid
wiring
Bad connection
Switch failure on tension
adjusting board and bad
circuit board
Bad tape data
Inadequate tension on X-Y
belt
Foreign substances in X-Y
rail
Failure of X/Y drivers
Heavy load on the frame
Disassemble the roller and
clean the roller and bush
bearing.
Check the plate connection
and change the circuit board
Check wiring and change
solenoid
Check connector
Change switch and circuit
board
Correct tape data
Adjust tension
Clean
Change X/Y drivers
Reduce speed of main shaft
rotation