Type | Biological Microscope |
---|---|
Eyepiece | WF10X |
Illumination | LED |
Condenser | Abbe condenser |
Power Supply | AC adapter |
Objective Lenses | 4X, 10X, 40X, 100X (oil) |
Focusing | Coaxial coarse and fine focusing |
Focusing System | Coaxial coarse and fine adjustment knobs |
Stage | Mechanical stage |
How to open the finger clip and place the slide on the stage.
How to select the lowest power objective.
Rotating nosepiece to higher magnification objectives.
Using stage knobs to position the specimen under the objective.
Setting binocular head barrels for a comfortable view.
Using left eye diopter for focus compensation between eyes.
Using the coarse focus knob to bring the specimen into focus.
Adjusting the iris diaphragm for contrast and depth of focus.
Using the fine focus control for sharp image.
Applying oil for fine resolution and brightness with 100XRD objective.
Technique for viewing fine details in transparent, low-contrast specimens.
Details on CMOS chip, picture size, color depth, memory, etc.
Resolution options (High, Medium, Low) and compression ratios.
Resolution and compression for video recording.
Options for single image, self-timer, video, and audio capture.
Settings for FINE (Q85) and NORMAL (Q95) compression ratios.
Settings for auto/manual exposure, white balance, and sharpness.
Configures the idle shutoff timer (60s, 120s, 180s, Never).
Options for image resolution and storage memory usage.
Options to turn date/time stamp on/off and set format.
Selects TV standard (NTSC or PAL).
Sets the auto exposure type (50 Hz or 60 Hz).
Selects the display language (English, Chinese, Japanese).
Precautions for electrical systems and component handling.
Corrections for image clarity, dust, and focus issues.
Warning against disassembling components; voids warranty.
Troubleshooting steps for apparent movement in the image.
Troubleshooting steps for output jack issues.
Troubleshooting steps for inability to focus.
Troubleshooting steps for a blank LCD screen.
Troubleshooting steps for focus losing itself.
Explanation for blue screen when USB is connected.
Troubleshooting steps for stiff focusing knobs.
Troubleshooting steps for illumination issues.
Steps to change the LCD screen language to English.
Troubleshooting steps for image appearance.
How to clean objective lenses using brushes, air, and lens tissue.
How to clean eyepiece lenses, often with breath and tissue.
Protecting the microscope from dust and proper storage methods.