12713140-003-2 Revision E.01 – January 2007 SSU-2000e Technical Reference 319
Chapter 8 Default Settings
User Changes to Factory Defaults
EIA-232-C Port
Comm Port Timeout
All three comm ports are set to 9600 baud,
Interactive Mode, CRLF, and Echo on
Five minutes for all (Interactive Mode). (Note:
the unit should have one user added, i.e. not
in the INITUSERTABLE state). If it is in the
INITUSERTABLE state, no timeout is applied.
No Timeout is assigned for the TL1 Mode
Ethernet IP Address IP Address 0.0.0.0
Gateway Address 0.0.0.0
Network Mask 255.255.255.0
Clock Module 1
Warmup Time 1200 s
Min Tau Limit 2E: 300 s
TYPE I: 150 s
3E: 150 s
Max Tau Limit 2E: 10 000 s
TYPE I:1200 s
3E: 1200 s
Min Lock Tau 2E: 1000 s
TYPE I: 150 s
3E: 1000 s
Max Lock Tau 2E: 9000 s
TYPE 1: 155 s
3E: 1200 s
Clk Switch AR On
Input Switch AutoReturn (AR)
Input Selection Mode Priority
Local Oscillator (LO) Off
Elevation Time 86400 seconds
PQL Setting 2E: 5
TYPE I: 6
3E: 8
Clock Module 2
Warmup Time 1200 s
Min Tau Limit 2E: 300 s
TYPE I: 150 s
3E: 150 s
Table 8-14. User Changes to Factory Default Settings (Continued)
Setting Factory Default User Changes