19
DigiZone
Control Reset & Reboot Guide
If your electronics are out of the parameters you set and you are unable to make any adjustments, follow
these steps to reset the electronics.
Section A – Reset DigiZone™ Electronics
1. Turn the red on/off power switch OFF, then back ON
2. Scroll the zones and press set to check the set points, reset if required
3. Press and hold the up arrow, then press and hold the zone button, hold both buttons together for 5
seconds to enter the common parameter adjusting mode.
1
st
parameter is the high alarm, set to 275° F – holding the set button and using the up and
down arrow keys. Press zone to go to the next parameter
2
nd
parameter is the low alarm, set to 125° F
3
rd
parameter is the auto fill probe delay, factory setting is 5 seconds
4
th
- 8
th
parameters are the temperature offset for Zone 1, 2, 3, 4 & 5 respectively. The
factory offsets for this machine are located on page 2 under the serial number
4. Press zone button to return to the operational mode
If the electronics do not respond to the above procedure, then a total system reboot is required
Section B – Total System Reboot
1. Turn red on/off power switch OFF and then turn the element breaker OFF
2. This can be difficult and may require assistance, press and hold zone, up arrow, down arrow and
set buttons simultaneously, and turn the power switch ON. Continue to hold all buttons during the
start up process and wait until the electronics turn on momentary, then off and then on again
BEFORE you release the buttons. If 2 ON cycles are not achieved, please try again.
3. Release all 4 buttons
4. This is a total system reboot and all of your parameters and your temperature set points will need to
be reentered. The electronics will show the factory temperature set points. Follow steps 1 -4 in
section A to program your set points.
5. Turn the element breaker ON
Section C – Fill in your Temperature Set Points for Reference
Temperature 1 Group Factory 2 Group 3 Group Factory
Zone 1 200° 200°
Zone 2 250° 200°
Zone 3 N/A N/A * OFF 200°
Zone 4 N/A N/A 250°
Zone 5 N/A N/A 250°
On a 2 group machine, lower the temperature setting for zone 3 until it reads OFF
Section D - Scroll Mode
Turn ON by pressing up & down arrows together until scrolling starts
Turn OFF scroll mode by pressing either the set or zone button