EasyManua.ls Logo

Synesso Sabre - Label Locations; Electrical Box Label; Electrical Cord Label; Frame Label

Synesso Sabre
20 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2
Label Locations
See this label on the electrical box
See this label on the end of the electrical cord.
See this label on the on inside edge of the frame under the drain tray on the front left side.
NOTE: For single line 220 vac use:
White wire as supply
Black wire as neutral
Green wire as earth (ground)
Materials Information
All stainless steel that comes into contact with the water supply, used to fabricate Synesso
espresso machines is 300 series
All brass fittings are low lead per the CA360 specifications or better
All electronic devices are lead free
All gaskets are made from a food contact safe material
Test Information
Brew (coffee) tanks are hydrostatically tested to 375 psi
Steam tanks are hydrostatically tested to 75 psi
The electrical system is subject to an electrical withstand test of: 1.20 kvac, at 5.00 mA, for 1
(one) second
This equipment is to be installed to
comply with the applicable federal,
state or local plumbing codes.

Related product manuals