stand-alone
operation
94
Conguration
Stand-alone automation
When the Filestore contains at least one .mkh mark le, you can congure FH Flyer to automatically load
a mark le and begin marking as soon as the head boots up. Typically the mark le will contain input/out-
put (I/O) automation that, in conjunction with corresponding wiring on the User Interface connector,
coordinates laser marking with automated parts handling equipment.
Hardware/software setup
1
Ensure that you have completed all the connections listed in the Getting Started chapter including
USB or Ethernet connections. If using an Ethernet connection, refer to the Conguration section in
the Getting Started chapter for information on setting Ethernet parameters.
2
Verify that I/O eld wiring on the User Interface connector matches the input and output states
specied in the mark le on the Drawing object’s Automation tab. For more information about Input/
Output automation, refer to the WinMark Pro Laser Marking Software User Guide or our Laser Mark-
ing FAQ at http://www.winmark.com/Support/FAQs.html.
3
Verify that the mark le’s Mark Count, on the Drawings Marking tab, is set to zero (0) or a value that
matches the number of parts you plan to mark.
Note: If Mark Count is one (1), then only one mark will occur each time the head is powered up.
4
After FH Flyer is booted-up up and operational, open WinMark Pro and go to the Device tab under
Tools / General Settings… .
5
Locate the Standalone Marking property and set it to Yes.
6
Choose a Standalone Mark Log Level depending on the amount of information you want FH Flyer
to report back to the computer—Normal is the default setting. Choose Verbose to display I/O progress
at each stage of the automation loop.
7
Set the Mark On Startup property to Yes.
8
Click the Startup Drawing property and enter a path and lename for the desired mark le. This le
must reside in the head’s Filestore.
For example, if the startup le is named Test.mkh and resides in the root directory of the Filestore,
enter “/Test.mkh” as the Startup Drawing. If this le is located in a folder named Startup File Folder,
then enter “/Startup File Folder/Test.mkh” for the Startup Drawing path and lename. Type the
case-sensitive path and lename without the quote (“”) symbols.
9
Verify the Use Control File property is set to No.
10
Click Apply to save the new settings and then click OK to exit the General Settings dialog.
Prepare to mark
1
Place a part in the eld of the focusing lens.