Sysmex KX-21 Operator’s Manual -- Revised January 2000 v
CHAPTER 9: FUNCTIONAL DESCRIPTION
1. INTRODUCTION.................................................................9-1
2. DETECTION PRINCIPLE.......................................................9-2
2.1 DC Detection Method......................................................9-2
2.2 Non-Cyanide Hemoglobin Analysis Method ...........................9-2
3. MEASURING UNIT HYDRAULIC SYSTEM BLOCK DIAGRAM.....9-4
4. CBC ANALYSIS..................................................................9-5
4.1 WBC/HGB Analysis Flow ................................................9-5
4.2 RBC/PLT Analysis Flow ..................................................9-7
4.3 Calculation of RBC Constant .............................................9-9
5. BLOOD CELL DISCRIMINATION CIRCUIT ............................ 9-10
5.1 WBC Discriminator ...................................................... 9-10
5.2 RBC Discriminator....................................................... 9-10
5.3 PLT Discriminator........................................................ 9-10
6. ANALYSIS OF HISTOGRAM ............................................... 9-11
6.1 Analysis of WBC Histogram............................................ 9-11
6.2 Analysis of RBC/PLT Histogram ...................................... 9-20
7. ELECTRIC SYSTEM .......................................................... 9-28
8. NAMES AND FUNCTIONS OF INSTRUMENTS........................ 9-30
8.1 Front Panel ................................................................ 9-30
8.2 Front Interior .............................................................. 9-31
8.3 Right Side Panel .......................................................... 9-32
8.4 Left Side Panel............................................................ 9-33
8.5 Left Side Interior.......................................................... 9-34
8.6 Rear Panel ................................................................. 9-35
CHAPTER 10: INSTRUMENT SETUP
1. INTRODUCTION............................................................... 10-1
2. SYSTEM SETUP................................................................ 10-2
3. DATE/TIME SETTINGS ...................................................... 10-7
4. PATIENT LIMIT...............................................................10-10
5. QC SETTINGS .................................................................10-13
6. HOST SETTINGS (OPTION)................................................10-16
7. PRINTER SETTINGS.........................................................10-21
8. PRINT SET VALUES .........................................................10-24
9. PERIPHERAL SETTINGS ...................................................10-25
10. FACTORY SETTINGS .......................................................10-27