The system must not be used together with solvents or volatile liquids that pose a health risk or are inflammable.
In the event that the system is used with non-approved soaps, chemicals or solvents, System Cleaners A/S disclaims
all liability.
If in doubt, please contact your soap or chemical supplier and read the supplier manual.
In the event that you use the system with chemicals that require mandatory labelling, or if the water temperature
exceeds 50°C, a low-pressure gun with an automatic closing device must be used.
In the event that you use the system without a gun with an automatic closing device together with chemicals that
require mandatory labelling, or water with a temperature that exceeds 50°C, System Cleaners A/S disclaims all
liability.
Pressure relief
After use shut the isolating valves over the equipment and relieve air and water pressure in hoses etc.
Flush injector system
After each use flush the injector system with warm water to avoid clogging of the injector.
MAINTENANCE
Water filter
Depending on the mains water quality it may be necessary to clean the water filter on a regular basis to prevent the
pump from stopping.
Water non-return valve
Water non-return valves are critical wear parts and should be replaced yearly.
Air filter
Depending on the quality of the compressed air it may be necessary to empty condensation collected in the air filter
bowl on a regular basis.
Injector system
The injector system consists of foot strainer, dosing valve, non-return valve and injector.
Chemical residues compromises the function of the injector and flushing with warm water after each use is required to
maintain trouble free operation.
Depending on the water quality it may be necessary to de-scale the water side of the injector on a regular basis
following the chemical supplier’s guidelines.