8 Installation
8.1 Safety information
Danger: Risk that MUB/F does not work in case of fire.
Use installation material with fire resistance classes that meet temperature requirements.
Warning: Danger from falling fan or fan parts.
Check the surface before installation for load bearing capacity.
Consider all static and dynamic loads when selecting hoisting equipment and fastening components.
General safety information
Installation may only be carried out by adequately qualified persons, details see Table 1 Qualifications, page 6.
Wear protective equipment during all work in the vicinity of the fan, details see 2.2 Personal protective equipment,
page 6.
Abide by the system-related conditions and requirements of the system manufacturer or plant constructor.
Do not dismantle or circumvent safety elements, or put them out of function.
Move the rotor of the fan by hand before you install it in order to check that it moves freely.
Provide contact and intake protection and ensure safety distances according to DIN EN ISO13857 and DIN 24167-1.
Prevent the possibility of foreign bodies being drawn in.
Use vibration dampers to prevent vibration transmissions. For example, article #37324 in our accessory range.
To reduce transmission of vibration to the duct system, we recommend flexible connections from our accessory
range, see chapter Accessories.
8.2 Preconditions
Ensure that the fan and all its components are undamaged.
Ensure that the information on the name plates (fan and motor) matches up with the operating conditions.
Ensure that there is enough space to install the fan.
Protect against dust and moisture when installing.
Fit the fans in such a way that there is sufficient access for troubleshooting, maintenance and repair.
Important
Overheating motor
Multiple fans: See the
adjacent image for minimum
distances between fans (2 x
A).
| 001

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SystemAir MUB Series and is the answer not in the manual?

SystemAir MUB Series Specifications

General IconGeneral
BrandSystemAir
ModelMUB Series
CategoryAir Conditioner
LanguageEnglish

Related product manuals