2020 Systems, LLC
INSTALLATION
Put New Restraint Into Service
A hard hat or other applicable head protection
should always be worn when working under or
around a dock leveler.
Always stand clear of platform lip when working in
front of the dock leveler.
1. Once all installation work is completed, disconnect
the external lifting device and lifting brackets.
2. Remove latch shipping bolt from latch mechanism.
Latch shipping bolt prevents PowerStop from raising
during shipment and can be safely removed after
install.