ATP/ASP/QTP/QSP Price Computing Scale User’s Guide
- 7 -
SECTIOIN 4 SETTING OF PARAMETERS
4. 1 ENTER SETTING MODE
To set the parameters it is necessary to enter a secure menu. This is done by
entering a password number when requested.
To enter the parameter menus press the TARE key during the initial counting of the
display after power turned on. The Weight Display will show "P n " requesting the
password number to be entered.
Press the "O" key four times. The display will show "Pn- - - -", Press the TARE key.
The Parameter menu has 18 functions that can be accessed using the PLU key to
cycle through the choices. The Weight Display will show the name of the functions.
Also you can press 0 to select F0, and key 2 to select F2…… To enter a function
press the TARE key. At any time press the ZERO key to return to weighing.
4. 2 PARAMETER SETTING TABLE
Weight Display
Description
F0 CAL
When the parameter menu show "F0" press the TARE key.
The display will then show "unLoAd" to request all weight be
removed from the platform.
After STABLE indicator on, press the TARE key to set the
zero point.
The display will then show the calibration weight requested,
press the TARE key to accept it.
The display will show "LOAd". place the calibration weight
on the scale. After STABLE indicator on, press the TARE key.
The scale will calibrate.
F1 RES
Set external resolution, press SAVE key to change
(3000/60000/duag range), press ZERO key to sure.
F2 UNIT
Set weighing unit, press SAVE key to change
(KILOS/POUNDS/HJ/HL/100), press ZERO key to sure.
F3 CAPA
Set capacity, Press SAVE key to select, press ZERO key to
sure..
F4 POINT
Set weighing decimal point, press SAVE key to select, press
ZERO key to sure.
F5 POINT
Set price decimal point, press SAVE key to select, press
ZERO key to sure.
F6 INIT ZERO
Set initialization zero range (auto zero range), press SAVE
key to select, press ZERO key to sure.
F7 RE ZERO
Set re zero range (manual zero range), press SAVE key to
select, press ZERO key to sure.