Trouble Shooting
Problem
Motor will not run
Motor hums but
cannot run or runs
slowly
Flow blows/circuit
breaker trips
repeatedly
Probable cause
1.Switch in OFF position
2.No electrical power at wall
outlet
3.Switch broke down
4. Motor broke down
Defective cable
1.Low voltage
2.Loose electrical
connections
3.Wrong gauge wire or
length of extension cord
4.Shorted or open motor
winding
1.Circuit overloaded
2.Wrong gauge wire or
length of extension cord
3.Motor shorted or seized
Suggested remedy
1.Make sure saw is plugged in
and switch is pressed
2.Check circuit breaker or fuse
at electrical panel.
3. Replace switch
4.Contact service center for
Replacing motor assembly.
5.Replace cable
1.Check voltage at wall outlet
with voltmeter.
2.Check all electrical
connections.
3.Check extension cord chart for
proper extension cord usage.
4.Contact service center for
Replacing motor assembly.
1.Disconnect other electrical
appliances from circuit or operate
saw on its own branch circuit.
2.Check extension cord chart for
proper extension cord usage.
3.Contact service center for
Replacing motor assembly.
13