OY1110 LoRaWAN Temperature and humidity sensor, User manual, Version 1.0
10
6 Specification
Accuracy and range
Temperature accuracy ± 0,2 °C (conditions 0 °C to +50 °C)
Temperature range -20 °C to +60 °C
Humidity accuracy ± 2% (conditions 10-90% RH)
Humidity range 0% to 100% non-condensing
Accuracy of ± 0,1 °C and ± 1,5% humidity available upon request
Connectivity
Network LoRaWAN
Frequency bands 868 MHz
Provisioning Over the air & personalization
Security
Algorithms AES-128
Hardware Cryptographic co-processor
Features Secure boot
Secure firmware upgrade
Hardware based ultra-secure key storage
Battery life
Battery life length 10 years (at 5-minute intervals, SF7)
Primary cell Lithium-thionyl 3.6V
Capacity 3.6 Ah
Size & Weight
Size 65 x 75 x 28 mm
Weight 75g
Configuration
Measurement intervals 1 minute – 1 week*
Transmission intervals 1 minute – 12 weeks*
*Default 15 minutes, configurable over the air