OY1110 LoRaWAN Temperature and humidity sensor, User manual, Version 1.0
16
0F: Delta time. bit7 = 0 => minutes
bit6-0 = 0F => 15 minutes
2EC: 748 => -5.2 °C now
3CD: 973 => 72.3 % Rh now
33D: 829 => 2.9 °C 15 minutes ago
382: 898 => 64.8 % Rh 15 minutes ago
39F: 927 => 12.7 °C 30 minutes ago
315: 789 => 53.9 % Rh 30 minutes ago
9.4 Downlink commands and queries
To control the sensor application, in-band commands and queries can be sent from the server
application. Contact your LoRaWAN network provider for in-band application API.
All downlink application communication is done on LoRaWAN port 1.
Downlink command network => device
Field
Value
Description
Note
Type
xx
0x01: Set
0x02: Query
0x03: Action
Index
xx
Command Index
Data
As defined for Command Index only applicable for set-commands