9.6 Uplink query response
When communication on LoRaWAN port 1 the following header is used:
Uplink command device => network
Field
Value
Description
Note
Type
xx
0x01: Data
0x02: Command NACK
Index
xx
Command Index
Data
As defined for Command Index (only for Type: Data)
9.6.1 Uplink status report
The uplink status report is sent unsolicited during Configure state and queried in
Operational state.
Example: Port 1: 01 20 00
01: Data type
20: Status command
00: Normal startup
For non-zero data, an error has occurred. Provide the error code in contacts with
Talkpool support.