During the cooling or dehumidifying mode, the condenser water will be drained into the internal water tank.
Since this unit is equipped with a self-evaporative system,the condenser water will be used to cool the
condenser making the unit run more efficiently. However, if the unit is used in high humidity areas, the water
may need to be drained out. When the water tank is full,the water full indicator at LED control panel will light
up and the compressor will stop running.The buzzer will s ound for 10 times every 5 minutes unit the water is
drained out.
After draining out the water, the alarm will stop and the unit will work normally. The compressor will start to run
five minutes after the power is back on.
You can drain the water out with a drainpipe (included).
Please follow the steps to drain the water:
1. Turn off the power;
2. Place a plate, pan or container under the drain
mouth;
3. Remove the water stopper from the drain mouth,
thus the condenser water will flow out of the water
tank.
4. If you want to continuously drain the water, please
use the drainpipe and follow the steps:
(1) Turn off the power;
(2) Place a plate, pan or container under the
drain mouth;
(3) Take off the water stopper
(4) Connect the supplied drainpipe to the water
mouth, and place a container at the end of
the pipe to collect the water. The condenser water will drai n out automatically into the
container.
(5) If you want to extend the drainpipe,you can use 9mm I.D. plastic pipe to connect with the
supplied drainpipe.
Attention: Do not move the unit while the water is full. It may cause the water to overflow on the floor
and damage the product.