18
Clean vacuum pump lter
The vacuum pump lter should be cleaned regulary (once a week, more often if the environment re-
quires it).
1. Remove the lter unit from the lter holder (a).
2. Open the lter unit (b).
3. Empty the lter unit and remove the lter inset in an upside-down position (c).
4. Carefully clean the lter inset using reduced compressed air.
5. The lter inset MUST be replaced when dirty or damaged.
6. Reassemble the lter unit and mount it in the lter holder with the lter unit lid in the upward direc-
tion (see gure).
7. Verify function of the lifter.
Clean the vacuum pump and suction foot lter regulary. Failure to clean the lters may cause the
pump to overheat or reduce lifting capacity.
Take care to mount the lter unit in the correct orientation during reassembly. Damage to the
pump may occur if the lter unit is mounted upside-down in the lter holder.