13. Sanitize and install the hopper cover. Lock the cover
into place. Position the open end of the vinyl tube into
the rear drip pan.
Figure 6-35
14. Press the BEATER key. Agitate the solution in the
freezing cylinder for five minutes.
Figure 6-36
15. With a pail beneath the door spout, open the draw
valve and drain all the solution from the mix hopper
and the freezing cylinder. Press the OFF key, and
close the draw valve.
Figure 6-37
CAUTION! The machine must not be placed in
Auto mode until all sanitizing solution has been removed
from the freezing cylinder and proper priming procedures
have been completed. Failure to follow this instruction
may result in damage to the freezing cylinder.
16. Repeat step 2 through step 15 for the remaining
freezing cylinder(s).
17. Disconnect the syrup connector in the sanitizing
solution.
18. Remove the right side panel and install the white rear
drip pan.
12184
13039b
!