13
Model 490 Operating Procedures
090807
Step 5
Place the freezer door gasket into the groove on the
back of the freezer door. Slide the front bearing over
the baffle rod so the flanged edge is against the
door. DO NOT LUBRICATE THE GASKET OR
BEARING.
Figure 10
Insert the baffle rod through the beater in the
freezing cylinder. With the door seated on the
freezer studs, install the handscrews. Tighten
equally in a criss-cross pattern to insure the door is
snug.
Figure 11
Rotate the draw valve bracket to the left and center
it into position by raising the draw arm and placing it
into the slotted groove of the draw valve bracket.
Note: The draw valve bracket must be positioned
with the notch to the left.
Figure 12
Step 6
Lay the air tube and hopper gasket in the bottom of
the mix hopper.
Figure 13