ENGLISH - 16
6.3.2 SEMI-AUTOMATIC CYCLE
- Press the SEMI-AUTOMATIC key to select
the semi-automatic thermal treatment cycle
with temperature and stand-by time control
(Fig. 1).
- The LEDs of the UP (), Confirm (◄►) and
DOWN () keys start flashing and the
numbers relative to the set of temperature to
be configured, between 30 and 90, appear
on the display: press the “UP ()” and
“DOWN ()” keys to increase or decrease
this value (Fig. 2). Once the wanted value is
reached, press the CONFIRM (◄►) key to
save the programming made (Fig. 3).
- After programming of the temperature set to
be reached, select the time during which this
temperature is kept constant.
- The LEDs of the UP (), Confirm (◄►) and
DOWN () keys start flashing and the
numbers relative to the set of time to be
configured, between 0' and 10' hours, appear
on the display: press the “UP ()” and
“DOWN ()” keys to increase or decrease
this value (Fig. 4).
- Once the wanted value is reached, press the
CONFIRM (◄►) key to save the
programming made and start the processing
cycle (Fig. 5).
By selecting heating temperatures between
65° and 85°C, the machine automatically
calculates the stand-by time required to
guarantee absolute product hygiene.
This time value can be modified at any time,
but it is strongly advised against as products
with excessively high bacterial loads may be
obtained.
- Once the programmed temperature is
reached and any standby time has passed,
the display flashes and the buzzer sounds
intermittently, to inform the operator that the
mixture can be extracted (fig.6). If this is not
Fig.4
Fig.1
Fig.2
Fig.3
Fig.5

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Taylor Frigomat CH02 Series and is the answer not in the manual?

Taylor Frigomat CH02 Series Specifications

General IconGeneral
BrandTaylor
ModelFrigomat CH02 Series
CategoryHeating System
LanguageEnglish